Mitsubishi Heavy Industries 12.5kW Standard Inverter Ducted System – FDUA125AVNXWVH

MHIA Standard Inverter Ducted 12.5kW FDUA125AVNXWVH Cooling: 12.5kW / Heating: 14.0kW / R32 Refrigerant Gas / 5 Year Manufacturer Warranty / Wi-Fi Control (Adapter Required) / Single Phase

$4,659.00

The Mitsubishi Heavy Industries FDUA Standard Inverter Ducted series has been engineered to deliver a quiet and discreet climate solution for your whole home. Available in Single and Three Phase power options. Comes with a 5 year parts and labour manufacturer’s warranty.

MHIA FDUA Standard Inverter Ducted systems come with the RC-EXZ3A Controller as standard. If you would like to upgrade to an alternate controller please contact our office for pricing.

The Split Store can organise hassle-free delivery and installation* of your inverter ducted system air conditioner within the Perth metro area, or you are welcome to collect your new air conditioner from our warehouse in Wangara.

 

Key Features:

High power mode for rapid cooling and heating.
Weekly and sleep timers.
Silent operation.
Dry operation to reduce humidity.
Economy mode to reduce power consumption.

 

*Delivery and installation costs subject to location and scope of works, please contact our office on 9302 2364 or at orders@splitstore.com.au if you have any questions.

Indoor FDUA125VH
Outdoor FDCA125VNX-W
Power source (Outdoor Unit) 1 Phase 240V 50Hz
*Operation data Nominal Capacity (Range) Cooling T1 kW 12.5 (5.0-14.0)
Heating H1 14.0 (4.0-17.0)
Heating H2 14.2
Power consumption Cooling T1 kW 3.83
Heating H1 3.68
Maximum power consumption kW 6.13
Running current Cooling T1 A 17
Heating H1 16.3
Inrush current, maximum current A 5, 29
EER Cooling T1 3.26
COP Heating H1 3.8
Sound power level (JIS C9612) Outdoor dB(A) 68
Sound pressure level (JIS C9612) Indoor dB (A) P-Hi:46 Hi:44 Me:42 Lo:38
Outdoor 54
External dimensions (HxWxD) Indoor mm 398×1150(+86)x650
Outdoor 1300x970x370
Net weight Indoor kg 52
Outdoor 97
Supply air connection mm 348×898
Return air connection mm 348×898
External Static Pressure (max) Pa 200
Airflow Indoor (Cooling) l/s P-Hi:717 Hi:650 Me:600 Lo:500
Indoor (Heating)
Refrigerant (R32) Quantity kg 4
Pre charged to pipe length m 30
Installation data Refrigerant piping Liquid line mm Ø9.52
Gas line Ø15.88
Connection method Flare Connection
Maximum pipe (one way) length m 100
Max vertical height diff. between O.U. and I.U. m 30 ( O.U. above I.U. ) / 15 ( O.U. below I.U. )
Controller RC-E5, RC-EXZ3A, RCH-E3 or RCN-KIT4-E2
Safety Pan (Optional) UA-SP2-E (Optional)
Motion Sensor (Optional) LB-KIT2
Demand response (AS4755) Yes
Outdoor air temperature (upper, lower limits) Cooling C -15 to 50
Heating C -20 to 20
* Operation data are conducted in accordance with AS/NZS 3823 standard.