Perth’s #1 Online
Air Conditioning Store

Perth’s #1 Online Air Conditioning Store

Mitsubishi Heavy Industries 14.0kW Standard Inverter Ducted System – FDUA140AVNXWVH

MHIA Standard Inverter Ducted 14.0kW FDUA140AVNXWVH Cooling: 14.0kW / Heating: 16.0kW / R32 Refrigerant Gas / 5 Year Manufacturer Warranty / Wi-Fi Control (Adapter Required) / Single Phase

$5,319.00

The Mitsubishi Heavy Industries FDUA Standard Inverter Ducted series has been engineered to deliver a quiet and discreet climate solution for your whole home. Available in Single and Three Phase power options. Comes with a 5 year parts and labour manufacturer’s warranty.

MHIA FDUA Standard Inverter Ducted systems come with the RC-EXZ3A Controller as standard. If you would like to upgrade to an alternate controller please contact our office for pricing.

The Split Store can organise hassle-free delivery and installation* of your inverter ducted system air conditioner within the Perth metro area, or you are welcome to collect your new air conditioner from our warehouse in Wangara.

 

Key Features

High power mode for rapid cooling and heating.
Weekly and sleep timers.
Silent operation.
Dry operation to reduce humidity.
Economy mode to reduce power consumption.

 

*Delivery and installation costs subject to location and scope of works, please contact our office on 9302 2364 or at orders@splitstore.com.au if you have any questions.

Set FDUA140AVNXWVH
Indoor FDUA140VH
Outdoor FDCA140VNX-W
Power source (Outdoor Unit) 1 Phase 240V 50Hz
*Operation data Nominal Capacity (Range) Cooling T1 kW 14.0 (5.0-14.5)
Heating H1 16.0 (4.0-18.0)
Heating H2 15.5
Power consumption Cooling T1 kW 4.02
Heating H1 4.19
Maximum power consumption kW 5.77
Running current Cooling T1 A 17.8
Heating H1 18.6
Inrush current, maximum current A 5, 30
EER Cooling T1 3.48
COP Heating H1 3.82
Sound power level (JIS C9612) Outdoor dB(A) 69
Sound pressure level (JIS C9612) Indoor dB (A) P-Hi:48 Hi:47 Me:43 Lo:38
Outdoor 54
External dimensions (HxWxD) Indoor mm 398x1450x930
Outdoor 1300x970x370
Net weight Indoor kg 66
Outdoor 97
Supply air connection mm 298×1064
Return air connection mm 2 X φ400
External Static Pressure (max) Pa 150
Airflow Indoor (Cooling) l/s P-Hi:1000 Hi:867 Me:733 Lo:600
Indoor (Heating)
Refrigerant (R32) Quantity kg 4
Pre charged to pipe length m 30
Installation data Refrigerant piping Liquid line mm Ø9.52
Gas line Ø15.88
Connection method Flare Connection
Maximum pipe (one way) length m 100
Max vertical height diff. between O.U. and I.U. m 30 ( O.U. above I.U. ) / 15 ( O.U. below I.U. )
Controller RC-E5, RC-EXZ3A, RCH-E3 or RCN-KIT4-E2
Safety Pan (Optional) NA
Motion Sensor (Optional) LB-KIT2
Demand response (AS4755) Yes
Outdoor air temperature (upper, lower limits) Cooling C -15 to 50
Heating C -20 to 20
* Operation data are conducted in accordance with AS/NZS 3823 standard.